Question # 1

Describe the principle of operation of solid state detector?

  • Ans 1: A solid state detector is a specially designed p-n junction operating under a reversed bias in which electron-hole pairs are produced by the incident radiation to cause a current pulse to flow through the external circuit.
Submit

Prepare Complete Set Wise Questions For Chapter 10 "ICS Part 2 Physics Chapter 21 Short Questions Preparation "

ICS Part 2 Physics Chapter 21 Short Questions Preparation - Set 1

Question # 1

Describe the principle of operation of solid state detector?

  • Ans 1: A solid state detector is a specially designed p-n junction operating under a reversed bias in which electron-hole pairs are produced by the incident radiation to cause a current pulse to flow through the external circuit.
Submit

ICS Part 2 Physics Chapter 21 Short Questions Preparation - Set 2

Question # 1

Define mass defect and binding energy.

  • Ans 1: Mass defect: The mass of the nucleus is always less than the total mass of the protons and neutrons that make up the nucleus,The difference of the two masses is called mass defect.
    Binding energy:The missing mass is converted into energy at the formation of the nucleus and is called binding energy.
Submit

ICS Part 2 Physics Chapter 21 Short Questions Preparation - Set 3

Question # 1

What are the relation between decay constantλand the half-line of a radioactive element?

  • Ans 1: The relation between decay constantλand the half line (T1/2) isλT1/2=0.693
Submit

ICS Part 2 Physics Chapter 21 Short Questions Preparation - Set 4

Question # 1

Wh Geiger counter is not suitable for fast counting?

  • Ans 1: Geiger counter is not suitable for fast counting because of its longer dead time.The positive ions take several time as long to reach the outer cathode,because positive ions are very massive than the electrons.During this time further incoming particle can not be counted,This time is called as the dead time of counter which delays fast counting system.
Submit

ICS Part 2 Physics Chapter 21 Short Questions Preparation - Set 5

Question # 1

Write down two advantages of solid state detector over geiger muller counter.

  • Ans 1: Solid state detector can count very fast than gas filled detector.
    Solid state detector is much smaller in size.
    It operates at low voltage.
Submit