1 |
Which of the following is not an adsorption indicator. |
Eosin
Bromocrsol green
Fluorescein
Phenolphthalein
|
2 |
Which of the following is not an organic precipitating agent. |
Diemethglyoxime
Cuperon
Oxime
Acetate
|
3 |
Which of the following anionic species is not separated by gravimetric analysis. |
Cl-
SO4
CH3COO-
PO4
|
4 |
Which of the following metal ion cannot be catimated by gravimetric analysis. |
K+
Ca<sup>2+</sup>
Al3+
Zn2+
|
5 |
Which of the following analytical techniques can be used to extract metal ion chelates. |
Solvent extractions
Evaporation
GC
Distillation
|
6 |
Which of the following is not a ligand or complexing agent. |
NH3
CH3COOH
EDTA
CN-
|
7 |
The number of bonds formed by the central atom is called its. |
Valence number
Complex number
Coordination number
Avogadro's number
|
8 |
Which of the following species is determined by complex metric titrations. |
K+
Na+
Ca+
Cl-
|
9 |
Complexing reactions are useful for which of the following method of analysis |
Gravimetry
Spectrophotometry
Interfering ions masking
All of the above
|
10 |
Amino acids are are important in biochemistry which of the following statements is not correct regarding amino acids. |
These are amphoteric substances tend to undergo internal protein transfer
In aqueous solutions these substances tend to undergo internal proton transfer
These for zwitter ion in aqueous medium
These always contain two amino groups.
|
11 |
Which of the following is the best indicator for titration of NH4OH with HCl. |
Methyl red
Methyl orange
Eosin
Phenolphthalein
|
12 |
Which of the following is the best indicator for titration of CH3COH with NaOH |
Methyl orange
Methyl red
Phenophthalein
Eosin
|
13 |
When CH3COOH is titrated against NaOH the pH as the equivalence point is. |
7
> 7
o<div>>7</div>
6.8
|
14 |
When HCl is titrated against NaOH , the pH at the equivalence point is. |
zero
> 7
< 7
14
|
15 |
An indicator for an acid base titration is a |
Weak acid
Weak base
Strong acid
Strong base
Both A and B
|
16 |
The point at which the reaction is observed to be complete is called. |
The equivalence point
The end point
The triplet point
The equilibrium point
|
17 |
An acid base titration involves a neutralization reaction in which an acid is reacted with an equivalent amount of base The titrant is always a strong acid or base The analyte may be |
Strong acid
Strong base
Weak acid and Weak base
All above
|
18 |
Which of the following is not a component of HPLC system. |
Pumps
Columns
Particle collector
Injection system.
|
19 |
Which of the following functional groups is not involved in ion exchange chromatography. |
Weak acids
Strong acids
Strong bases
Carbohydrates
|
20 |
Which of the following statement is not related with the advantages of TLC. |
A variety of adsorbents can be used
The thickness of adsorbent can be varied
Fluorescence can be introduced
Different detectors can be used
|
21 |
Which of the following materials is not suitable as adsorbent for chromatography. |
Silica gel
Activated charocal
Alumina
Calciu7m chloride
|
22 |
Which of the following techniques is capable of seperating minute quantities of the substances in a relatively short times with high resolutions. |
Gel electrophoresis
Capillary electrophoresis
GC
HPLC
|
23 |
Which of the following technique is used to separate substance based on their charge to mass ratio. |
HPLC
HPTLC
GC
Electrophoresis
|
24 |
Which of the following detector is used in HPLC system. |
Differential refractometer detector
UV detector
Diode array detector
All above
|
25 |
Which of the following detector is used for compounds containing electronegative atoms. |
Mass specdtrometer
ECD
TCD
UV-detector
|
26 |
Which of the following detector is used in GC analysis |
Thermal conductivity detector
Flame ionization detector
Mass spectrometer
All above
|
27 |
A well packed column may hve |
100 plates /m
1000 plates /m
10 plates /m
10,000 plates/m
|
28 |
Which of the following information is correct about a typical packed column in GC. |
10-100 m long and 2 to 6 cm to diameter
1-10 m long and 0.2 to 0.6 cm in diameter
0.1-1 m long and 0.02 to 0.00 cm in diameter
None of the above
|
29 |
Which of the following gas is not used as carrier gas in GC. |
Argon
Nitrogen
Helium
CO2
|
30 |
Which of the following is not a component of a gas chromatography system. |
Carrier gas
Capillary column
Packed column
Cathode lamp
|